Cobalt-60 (Half life: 5.27 years)
The active part is either cobalt-nickel alloy or metallic cobalt encapsulated in stainless steel (KO-36) and sealed by argon arc welding.
- Standard Capsule design Sources for Gauges
Recommended working life: 10 years
Activity tolerance: ± 10% from nominal
Type code |
Overall dimensions D [mm] L [mm] |
Maximum active dimensions [mm] [mm] |
Maximum equivalent activity GBq mCi |
ISO classification
|
||||
CoS-15HH* |
6.4 |
16 |
4 |
4 |
55.5 |
1500 |
C 66646 |
*qualified as special-form radioactive material samples
- Capsule types for recapsulate old sources
Type code |
Overall dimensions D [mm] L [mm] |
Maximum active dimensions [mm] [mm] |
Maximum equivalent activity GBq mCi |
ISO classification
|
||||
CoS-16H |
8 |
13 |
5 |
10 |
74 |
2000 |
C 64545 |
|
CoS-17H |
8 |
8 |
– |
5 |
55.5 |
1500 |
C 64545 |
Type code |
Overall dimensions D [mm] L [mm] |
Maximum active dimensions [mm] [mm] |
Maximum equivalent activity GBq mCi |
ISO classification
|
||||
CoS-18H |
12 |
24 |
5 |
10 |
74 |
2000 |
C 64545 |
|
CoS-19H |
12 |
19 |
5 |
5 |
55.5 |
1500 |
C 64545 |
|
CoS-24H |
14 |
35 |
11 |
19 |
55.5 |
1500 |
C 64545 |
Type code |
Overall dimensions D [mm] L [mm] |
Maximum active dimensions [mm] [mm] |
Maximum equivalent activity GBq mCi |
ISO classification
|
||||
CoS-21H |
6 |
6 |
4 |
4 |
55.5 |
1500 |
C 64545 |
|
CoS-22H |
5 |
5 |
3 |
3 |
37 |
1000 |
C 64545 |
- Standard Capsule design for Teletherapy
Recommended working life: 20 years
Activity tolerance: ± 10% from nominal
Type code |
Overall dimensions D [mm] L [mm] |
Maximum active dimensions d [mm] l [mm] |
Maximum equivalent activity TBq Ci |
ISO classification
|
||||
CoS-57HH* |
23.5 |
36.5 |
19.5 |
29 |
222 |
6000 |
E 64546 |
*qualified as special-form radioactive material samples
- Standard Capsule design for Industry
Recommended working life: 20 years
Activity tolerance: ± 10% from nominal
All types are qualified as special-form radioactive material samples
Type code |
Overall dimensions D [mm] L |
Active dimensions d [mm] l [mm] |
Maximum equivalent activity TBq Ci |
MSZ classification
|
||||
CoS-43HH |
11 |
451 |
7 |
437 |
111 |
3000 |
E 64434 |
|
CoS-43HH-M |
11 |
451 |
7 |
437 |
450 |
12150 |
E 64434 |
|
CoS-44HH-N |
11 |
220 |
7 |
207 |
296 |
8000 |
E 64434 |
|
CoS-45HH |
11 |
81.5 |
7 |
69 |
112 |
3000 |
E 64546 |