Irradiators:
The OB-SERVO irradiators are designed for research irradiation tasks or irradiation of medical goods in small and medium scale.
The following table contains the types of the series with the main parameters:
OB-SERVO |
IGNIS |
SANGUIS |
LA/D |
D |
W |
Classification |
Research |
Research |
Research and Calibration |
Semi – Multipurpose |
Semi – Multipurpose |
IAEA Category |
Category I. |
Category I. |
Category II. |
Category II. |
Category IV. |
Storage Type |
Dry Storage |
Dry Storage |
Dry Storage |
Dry Storage |
Wet Storage |
Source Details |
|||||
Sealed Source |
Co-60 |
Co-60 |
Co-60 |
Co-60 |
Co-60 |
Maximum Activity |
888 TBq (24 kCi) |
444 TBq (12 kCi) |
111 TBq (3 kCi) |
3700 TBq (100 kCi) |
7400 TBq (200 kCi) |
Source Type |
CoS-44 HH-N |
CoS-44 HH-N CoS-45 HH CoS-57 HH |
CoS-57 HH |
CoS-44 HH-N |
CoS-43 HH-M CoS-44 HH-N |
Source Dimensions |
Ø11×220 mm |
Ø11×220 mm Ø11×81.5 mm Ø23.5×36.5 mm |
Ø23.5×36.5 mm |
Ø11×220 mm |
Ø11×451 mm, Ø11×220 mm |
Source Cage Type |
Cylindrical |
Cylindrical |
Special Drawer |
Special Drawer |
Cylindrical |
Source Cage Capacity |
48 pcs |
8 pcs |
1 pc |
12 pcs |
20 pcs |
Configuration |
Fixed sources with rotating canister |
Source turn (absorbent unit) and rotating canister |
Source hoist with collimator and absorbent unit |
Source hoist with turntable system |
Source hoist with turntable system |
Radiation details |
|||||
Maximum Central Dose Rate |
10 kGy/h |
2.5 kGy/h |
– |
– |
– |
Dose Uniformity (Max) |
± 20% |
± 20% |
– |
– |
– |
Dose Rate at 1 m |
– |
– |
30 Gy/h |
1 kGy/h |
1.5 kGy/h |
Accessories |
|||||
Pressurized Air Supply |
✓ |
– |
✓ |
✓ |
✓ |
Ventilation System |
– |
✓ |
– |
✓ |
✓ |
Water Treatment |
– |
– |
– |
– |
✓ |
Safety and Security System |
✓ |
✓ |
✓ |
✓ |
✓ |
Control System |
✓ |
✓ |
✓ |
✓ |
✓ |
Electric Requirements |
50 Hz, 230 V – with ground (Single-Phase Power) |
Services: