Co-60 radioactive source

Co-60, Cobalt-60 (Half life: 5.27 years)

The active part is either cobalt-nickel alloy or metallic cobalt encapsulated in stainless steel (KO-36) and sealed by argon arc welding.
  • Standard Capsule design Sources for Gauges
Recommended working life: 10 years Activity tolerance: ± 10% from nominal

Type code

Overall dimensions

D [mm] L [mm]

Maximum

active dimensions

 [mm]   [mm]

Maximum

equivalent activity

GBq      mCi

ISO

classification

CoS-15HH*

6.4

16

4

4

55.5

1500

C 66646

*qualified as special-form radioactive material samples

  • Capsule types for recapsulate old sources

Type code

Overall dimensions

D [mm] L [mm]

Maximum

active dimensions

[mm]     [mm]

Maximum

equivalent activity

GBq      mCi

ISO

classification

CoS-16H

8

13

5

10

74

2000

C 64545

CoS-17H

8

8

5

55.5

1500

C 64545

Type code

Overall dimensions

D [mm] L [mm]

Maximum

active dimensions

[mm]      [mm]

Maximum

equivalent activity

GBq       mCi

ISO

classification

CoS-18H

12

24

5

10

74

2000

C 64545

CoS-19H

12

19

5

5

55.5

1500

C 64545

CoS-24H

14

35

11

19

55.5

1500

C 64545

Type code

Overall dimensions

D [mm] L [mm]

Maximum

active dimensions

[mm]     [mm]

Maximum

equivalent activity

GBq      mCi

ISO

classification

CoS-21H

6

6

4

4

55.5

1500

C 64545

CoS-22H

5

5

3

3

37

1000

C 64545

  • Standard Capsule design for Teletherapy
Recommended working life: 20 years Activity tolerance: ± 10% from nominal

Type code

Overall dimensions

D [mm] L [mm]

Maximum

active dimensions

d [mm]     l [mm]

Maximum

equivalent activity

 TBq         Ci

ISO

classification

CoS-57HH*

23.5

36.5

19.5

29

222

6000

E 64546

*qualified as special-form radioactive material samples

  • Standard Capsule design for Industry
Recommended working life: 20 years Activity tolerance: ± 10% from nominal All types are qualified as special-form radioactive material samples

Type code

Overall dimensions

D [mm]        L

 

Active dimensions

d [mm]    l [mm]

Maximum

equivalent activity

TBq       Ci

MSZ

classification

CoS-43HH

11

451

7

437

111

3000

E 64434

CoS-43HH-M

11

451

7

437

450

12150

E 64434

CoS-44HH-N

11

220

7

207

296

8000

E 64434

CoS-45HH

11

81.5

7

69

112

3000

E 64546

We also offer various irradiators designed for research irradiation tasks or irradiation of medical goods in small and medium scale. For further information please, click here. If you have further technical questions please do not hesitate to contact us.

Cookies help us deliver our services. By using our services, you agree to our use of cookies. More Information

Happy Easter!